E6MCPF4 Intermediate Timber Floor Within A Dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Masonry Cavity, Partial fill, E6 Intermediate floor within a dwelling

E5MCFF27 Concrete Ground Bearing Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E11MCFF4 Pitched Roof, Eaves, Insulation At Rafter Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)...
Appears in:
Full fill, Masonry Cavity, E11 Eaves (insulation at rafter level)

E18MCFF9 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)...
Appears in:
Full fill, Party Wall, E18 P1 Party wall between

E1MCPF6 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
E17 Corner (inverted), Masonry Cavity, Partial fill

E5MCPF19 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Partial Fill Insulation
100mm Aircrete Block Inner Leaf (...
Appears in:
Masonry Cavity, Partial fill, E5 Ground floor

E3MCFF6 Sill
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Full fill, Masonry Cavity, E3 Sill

E6MCPF5 Intermediate Timber Floor Within A Dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)...
Appears in:
Masonry Cavity, Partial fill, E6 Intermediate floor within a dwelling

E5MCFF28 Suspended In-Situ Concrete Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E11MCFF5 Pitched Roof, Eaves, Insulation At Rafter Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)...
Appears in:
Full fill, Masonry Cavity, E11 Eaves (insulation at rafter level)