Construction Details
Use the search and filter to find the construction details you're looking for. Your current filter is displayed below.

E12MCFF6 Pitched Roof, Gable, Insulation At Ceiling Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Full fill, Masonry Cavity, E12 Gable (insulation at ceiling level)

P1PCFF2 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
Masonry Party Wall
2 x 100mm Aircrete Block (0.19W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0....
Appears in:
Full fill, Masonry Cavity, Party Wall, E18 P1 Party wall between

E2MCPF8 STEEL LINTEL, OPEN BACK - NO CONTINUOUS BASEPLATE
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK...
Appears in:
Masonry Cavity, Partial fill, E2 Other lintels

E1MCFF4 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
E17 Corner (inverted), Full fill, Masonry Cavity

E5MCPF24 Concrete Ground Bearing Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)...
Appears in:
Masonry Cavity, Partial fill, E5 Ground floor

E5MCFF17 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E10MCPF4 Pitched Roof, Eaves, Insulation At Ceiling Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)...
Appears in:
Masonry Cavity, Partial fill, E10 Eaves (insulation at ceiling level)

E5MCFF33 Suspended In-Situ Concrete Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E13MCFF4 Pitched Roof, Gable, Insulation At Rafter Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Full fill, Masonry Cavity, E13 Gable (insulation at rafter level)

E13MCFF5 Pitched Roof, Gable, Insulation At Rafter Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)...
Appears in:
Full fill, Masonry Cavity, E13 Gable (insulation at rafter level)