Construction Details
Use the search and filter to find the construction details you're looking for. Your current filter is displayed below.

E5MCFF16 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E7MCPF6 Precast Concrete Separating Floor Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Masonry Cavity, Partial fill, E7 Intermediate floor between dwelling

E5MCFF32 Suspended In-Situ Concrete Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E5MCFF33 Suspended In-Situ Concrete Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E13MCFF4 Pitched Roof, Gable, Insulation At Rafter Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Full fill, Masonry Cavity, E13 Gable (insulation at rafter level)

P1PCFF2 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
Masonry Party Wall
2 x 100mm Aircrete Block (0.19W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0....
Appears in:
Full fill, Masonry Cavity, Party Wall, E18 P1 Party wall between

E2MCPF8 STEEL LINTEL, OPEN BACK - NO CONTINUOUS BASEPLATE
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK...
Appears in:
Masonry Cavity, Partial fill, E2 Other lintels

E1MCFF4 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
E17 Corner (inverted), Full fill, Masonry Cavity

E5MCPF24 Concrete Ground Bearing Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)...
Appears in:
Masonry Cavity, Partial fill, E5 Ground floor

E5MCFF17 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor