Construction Details
Use the search and filter to find the construction details you're looking for. Your current filter is displayed below.

E11MCPF2 Pitched roof eaves, between and under rafter insulation
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK...
Appears in:
Masonry Cavity, Partial fill, E11 Eaves (insulation at rafter level)

E18MCPF3 Masonry separating wall – External wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Dense Concrete Block λ ≤1.33 W/mK Inner Leaf...
Appears in:
Masonry Cavity, Partial fill, E18 P1 Party wall between

E17MCPF4 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Masonry Cavity, Partial fill

E5MCFF6 Suspended Beam and Block Floor – 100mm Insulation Below Screed
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ =1.33 W/mK
Beam and Block...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E18MCFF2 Masonry separating wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Lightweight Concrete Block λ ≤ 0.60 W/mK Inner...
Appears in:
Full fill, Masonry Cavity, E18 P1 Party wall between

E5MCPF4 Suspended beam and block floor – 100mm Insulation below screed
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/Mk...
Appears in:
Masonry Cavity, Partial fill, E5 Ground floor

E5MCFF16 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E7MCPF6 Precast Concrete Separating Floor Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Masonry Cavity, Partial fill, E7 Intermediate floor between dwelling

E5MCFF32 Suspended In-Situ Concrete Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor

E12MCFF6 Pitched Roof, Gable, Insulation At Ceiling Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Full fill, Masonry Cavity, E12 Gable (insulation at ceiling level)