Construction Details
Use the search and filter to find the construction details you're looking for. Your current filter is displayed below.

E1MCPF3 Insulated Steel Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Partial Fill...
Appears in:
E17 Corner (inverted), Masonry Cavity, Partial fill

E5MCPF11 Suspended beam and block floor – 150mm Insulation below screed
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK...
Appears in:
Masonry Cavity, Partial fill, E5 Ground floor

E16MCPF1 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK...
Appears in:
Masonry Cavity, Partial fill, E16 Corner (normal)

E12MCPF4 Pitched Roof, Gable, Insulation At Ceiling Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Masonry Cavity, Partial fill, E12 Gable (insulation at ceiling level)

E18MCPF12 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Masonry Cavity, Partial fill, E18 P1 Party wall between

E12MCFF2 Pitched roof gable, insulation at ceiling level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill...
Appears in:
Full fill, Masonry Cavity, E12 Gable (insulation at ceiling level)

E2MCPF1 Independent Concrete Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block Inner Leaf λ ≤ 0.28 W/...
Appears in:
Masonry Cavity, Partial fill, E2 Other lintels

E5MCPF12 Suspended beam and block floor – 150mm Insulation below screed
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial...
Appears in:
Masonry Cavity, Partial fill, E5 Ground floor

E16MCPF2 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK...
Appears in:
Masonry Cavity, Partial fill, E16 Corner (normal)

E12MCPF5 Pitched Roof, Gable, Insulation At Ceiling Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK...
Appears in:
Masonry Cavity, Partial fill, E12 Gable (insulation at ceiling level)